ACPITZ(4) NetBSD Kernel Interfaces Manual ACPITZ(4)
NAME
acpitz -- ACPI Thermal Zone
SYNOPSIS
acpitz* at acpi?
DESCRIPTION
The acpitz driver supports so-called ACPI ``Thermal Zones''. The temper- ature can be monitored by the envsys(4) API or the envstat(8) command. The distinction between ``active'' and ``passive'' cooling is central to the abstractions behind acpitz. These are inversely related to each other: 1. Active cooling means that the system increases the power consump- tion of the machine by performing active thermal management (for example, by turning on a fan) in order to reduce the temperatures. 2. Passive cooling means that the system reduces the power consump- tion of devices at the cost of system performance (for example, by lowering the CPU frequencies) in order to reduce the temperatures. Only active cooling is currently supported on NetBSD. It should be also noted that the internal functioning of these cooling policies vary across machines. On some machines the operating system may have little control over the thermal zones as the firmware manages the thermal control internally, whereas on other machines the policies may be exposed to the implementation at their full extent.
EVENTS
The acpitz driver knows about the active cooling levels, the current tem- peratures, and critical, hot, and passive temperature thresholds (as sup- ported by the hardware). The driver is able to send events to powerd(8) when the sensor's state has changed. When a Thermal Zone is either crit- ical or ``hot'', the /etc/powerd/scripts/sensor_temperature script will be invoked with a critical-over event. The critical temperature is the threshold for system shutdown. Depending on the hardware, the mainboard will take down the system instantly and no event will have a chance to be sent.
SEE ALSO
acpi(4), acpifan(4), envsys(4), envstat(8), powerd(8)
HISTORY
The acpitz driver appeared in NetBSD 2.0.
AUTHORS
Jared D. McNeill <jmcneill@invisible.ca>
CAVEATS
While no pronounced bugs are known to exist, several caveats can be men- tioned: · Passive cooling is not implemented. · There is no user-controllable way to switch between active and pas- sive cooling, although the specifications support such transforms on some machines. · The ``hot'' temperature is a threshold in which the system ought to be put into S4 sleep. This sleep state (``suspend to disk'') is not supported on NetBSD. NetBSD 8.3 January 9, 2011 NetBSD 8.3
Powered by man-cgi (2024-08-26). Maintained for NetBSD by Kimmo Suominen. Based on man-cgi by Panagiotis Christias.