DD(1) NetBSD General Commands Manual DD(1)
NAME
dd -- convert and copy a file
SYNOPSIS
dd [operand ...]
DESCRIPTION
The dd utility copies the standard input to the standard output. Input data is read and written in 512-byte blocks. If input reads are short, input from multiple reads are aggregated to form the output block. When finished, dd displays the number of complete and partial input and output blocks and truncated input records to the standard error output. The following operands are available: bs=n Set both input and output block size, superseding the ibs and obs operands. If no conversion values other than noerror, notrunc or sync are specified, then each input block is copied to the output as a single block without any aggregation of short blocks. cbs=n Set the conversion record size to n bytes. The conversion record size is required by the record oriented conversion val- ues. count=n Copy only n input blocks. files=n Copy n input files before terminating. This operand is only applicable when the input device is a tape. ibs=n Set the input block size to n bytes instead of the default 512. if=file Read input from file instead of the standard input. iflag=flags Use comma-separated flags when calling open(2) for the input file. The possible values are O_ flags documented in open(2), specified as lowercase and with the leading O_ removed. Default value is rdonly. iseek=n Seek on the input file n blocks. This is synonymous with skip=n. msgfmt=fmt Specify the message format fmt to be used when writing informa- tion to standard output. Possible values are: quiet turns off information summary report except for errors and progress. posix default information summary report as specified by POSIX. human default information summary report extended with human-readable values. When fmt does not correspond to any value given above, it con- tains a string that will be used as format specifier for the information summary output. Each conversion specification is introduced by the character %. The following ones are avail- able: b total number of bytes transferred B total number of bytes transferred in humanize_number(3) format e speed transfer E speed transfer in humanize_number(3) format i number of partial input block(s) I number of full input block(s) o number of partial output block(s) O number of full output block(s) s time elapsed since the beginning in ``seconds.ms'' format p number of sparse output blocks t number of truncated blocks w number of odd-length swab blocks P singular/plural of ``block'' depending on number of sparse blocks T singular/plural of ``block'' depending on number of truncated blocks W singular/plural of ``block'' depending on number of swab blocks obs=n Set the output block size to n bytes instead of the default 512. of=file Write output to file instead of the standard output. Any regu- lar output file is truncated unless the notrunc conversion value is specified. If an initial portion of the output file is skipped (see the seek operand) the output file is truncated at that point. oflag=flags Same as iflag but for the call to open(2) on the output file. The default value is creat, which should be explicitly added in oflag in order to output to a nonexistent file. The default or specified value is or'ed with rdwr for a first attempt, then on failure with wronly on a second attempt. In both cases, trunc is automatically added if none of oseek, seek, or conv=notrunc operands are used, oseek=n Seek on the output file n blocks. This is synonymous with seek=n. seek=n Seek n blocks from the beginning of the output before copying. On non-tape devices, an lseek(2) operation is used. Otherwise, existing blocks are read and the data discarded. If the user does not have read permission for the tape, it is positioned using the tape ioctl(2) function calls. If the seek operation is past the end of file, space from the current end of file to the specified offset is filled with blocks of NUL bytes. skip=n Skip n blocks from the beginning of the input before copying. On input which supports seeks, an lseek(2) operation is used. Otherwise, input data is read and discarded. For pipes, the correct number of bytes is read. For all other devices, the correct number of blocks is read without distinguishing between a partial or complete block being read. progress=n Switch on display of progress if n is set to any non-zero value. This will cause a ``.'' to be printed (to the standard error output) for every n full or partial blocks written to the output file. conv=value[,value...] Where value is one of the symbols from the following list. ascii, oldascii The same as the unblock value except that characters are translated from EBCDIC to ASCII before the records are converted. (These values imply unblock if the op- erand cbs is also specified.) There are two conversion maps for ASCII. The value ascii specifies the recom- mended one which is compatible with AT&T System V UNIX. The value oldascii specifies the one used in historic AT&T and pre- 4.3BSD-Reno systems. block Treats the input as a sequence of newline or end-of- file terminated variable length records independent of input and output block boundaries. Any trailing new- line character is discarded. Each input record is con- verted to a fixed length output record where the length is specified by the cbs operand. Input records shorter than the conversion record size are padded with spaces. Input records longer than the conversion record size are truncated. The number of truncated input records, if any, are reported to the standard error output at the completion of the copy. ebcdic, ibm, oldebcdic, oldibm The same as the block value except that characters are translated from ASCII to EBCDIC after the records are converted. (These values imply block if the operand cbs is also specified.) There are four conversion maps for EBCDIC. The value ebcdic specifies the recommended one which is compatible with AT&T System V UNIX. The value ibm is a slightly different mapping, which is compatible with the AT&T System V UNIX ibm value. The values oldebcdic and oldibm are maps used in historic AT&T and pre 4.3BSD-Reno systems. lcase Transform uppercase characters into lowercase charac- ters. noerror Do not stop processing on an input error. When an input error occurs, a diagnostic message followed by the current input and output block counts will be writ- ten to the standard error output in the same format as the standard completion message. If the sync conver- sion is also specified, any missing input data will be replaced with NUL bytes (or with spaces if a block ori- ented conversion value was specified) and processed as a normal input buffer. If the sync conversion is not specified, the input block is omitted from the output. On input files which are not tapes or pipes, the file offset will be positioned past the block in which the error occurred using lseek(2). notrunc Do not truncate the output file. This will preserve any blocks in the output file not explicitly written by dd. The notrunc value is not supported for tapes. osync Pad the final output block to the full output block size. If the input file is not a multiple of the out- put block size after conversion, this conversion forces the final output block to be the same size as preceding blocks for use on devices that require regularly sized blocks to be written. This option is incompatible with use of the bs=n block size specification. sparse If one or more non-final output blocks would consist solely of NUL bytes, try to seek the output file by the required space instead of filling them with NULs. This results in a sparse file on some file systems. swab Swap every pair of input bytes. If an input buffer has an odd number of bytes, the last byte will be ignored during swapping. sync Pad every input block to the input buffer size. Spaces are used for pad bytes if a block oriented conversion value is specified, otherwise NUL bytes are used. ucase Transform lowercase characters into uppercase charac- ters. unblock Treats the input as a sequence of fixed length records independent of input and output block boundaries. The length of the input records is specified by the cbs op- erand. Any trailing space characters are discarded and a newline character is appended. Where sizes are specified, a decimal number of bytes is expected. Two or more numbers may be separated by an ``x'' to indicate a product. Each number may have one of the following optional suffixes: b Block; multiply by 512 k Kibi; multiply by 1024 (1 KiB) m Mebi; multiply by 1048576 (1 MiB) g Gibi; multiply by 1073741824 (1 GiB) t Tebi; multiply by 1099511627776 (1 TiB) w Word; multiply by the number of bytes in an integer When finished, dd displays the number of complete and partial input and output blocks, truncated input records and odd-length byte-swapping blocks to the standard error output. A partial input block is one where less than the input block size was read. A partial output block is one where less than the output block size was written. Partial output blocks to tape devices are considered fatal errors. Otherwise, the rest of the block will be written. Partial output blocks to character devices will produce a warning message. A truncated input block is one where a vari- able length record oriented conversion value was specified and the input line was too long to fit in the conversion record or was not newline ter- minated. Normally, data resulting from input or conversion or both are aggregated into output blocks of the specified size. After the end of input is reached, any remaining output is written as a block. This means that the final output block may be shorter than the output block size. If dd receives a SIGINFO signal (see the status argument for stty(1)), the current input and output block counts will be written to the standard error output in the same format as the standard completion message. If dd receives a SIGINT signal, the current input and output block counts will be written to the standard error output in the same format as the standard completion message and dd will exit.
EXIT STATUS
The dd utility exits 0 on success and >0 if an error occurred.
EXAMPLES
To print summary information in human-readable form: dd if=/dev/zero of=/dev/null count=1 msgfmt=human To customize the information summary output and print it through unvis(3): dd if=/dev/zero of=/dev/null count=1 \ msgfmt='speed:%E, in %s seconds\n' 2>&1 | unvis
SEE ALSO
cp(1), mt(1), tr(1)
STANDARDS
The dd utility is expected to be a superset of the IEEE Std 1003.2 (``POSIX.2'') standard. The files and msgfmt operands and the ascii, ebcdic, ibm, oldascii, oldebcdic and oldibm values are extensions to the POSIX standard. NetBSD 7.1.2 March 18, 2015 NetBSD 7.1.2
Powered by man-cgi (2024-08-26). Maintained for NetBSD by Kimmo Suominen. Based on man-cgi by Panagiotis Christias.