sigaction(2) - NetBSD Manual Pages

SIGACTION(2)              NetBSD Programmer's Manual              SIGACTION(2)


NAME
sigaction - software signal facilities
LIBRARY
Standard C Library (libc, -lc)
SYNOPSIS
#include <signal.h> struct sigaction { void (*sa_handler)(int); sigset_t sa_mask; int sa_flags; }; int sigaction(int sig, const struct sigaction *act, struct sigaction *oact);
DESCRIPTION
The system defines a set of signals that may be delivered to a process. Signal delivery resembles the occurrence of a hardware interrupt: the signal is blocked from further occurrence, the current process context is saved, and a new one is built. A process may specify a handler to which a signal is delivered, or specify that a signal is to be ignored. A pro- cess may also specify that a default action is to be taken by the system when a signal occurs. A signal may also be blocked, in which case its delivery is postponed until it is unblocked. The action to be taken on delivery is determined at the time of delivery. Normally, signal han- dlers execute on the current stack of the process. This may be changed, on a per-handler basis, so that signals are taken on a special signal stack. Signal routines execute with the signal that caused their invocation blocked, but other signals may yet occur. A global signal mask defines the set of signals currently blocked from delivery to a process. The signal mask for a process is initialized from that of its parent (normal- ly empty). It may be changed with a sigprocmask(2) call, or when a sig- nal is delivered to the process. When a signal condition arises for a process, the signal is added to a set of signals pending for the process. If the signal is not currently blocked by the process then it is delivered to the process. Signals may be delivered any time a process enters the operating system (e.g., during a system call, page fault or trap, or clock interrupt). If multiple sig- nals are ready to be delivered at the same time, any signals that could be caused by traps are delivered first. Additional signals may be pro- cessed at the same time, with each appearing to interrupt the handlers for the previous signals before their first instructions. The set of pending signals is returned by the sigpending(2) function. When a caught signal is delivered, the current state of the process is saved, a new signal mask is calculated (as described below), and the signal handler is invoked. The call to the handler is arranged so that if the signal han- dling routine returns normally the process will resume execution in the context from before the signal's delivery. If the process wishes to re- sume in a different context, then it must arrange to restore the previous context itself. When a signal is delivered to a process a new signal mask is installed for the duration of the process' signal handler (or until a sigprocmask(2) call is made). This mask is formed by taking the union of the current signal mask, the signal to be delivered, and the signal mask associated with the handler to be invoked, sa_mask. sigaction() assigns an action for a specific signal. If act is non-zero, it specifies an action (SIG_DFL, SIG_IGN, or a handler routine) and mask to be used when delivering the specified signal. If oact is non-zero, the previous handling information for the signal is returned to the user. Once a signal handler is installed, it remains installed until another sigaction() call is made, or an execve(2) is performed. A signal-specif- ic default action may be reset by setting sa_handler to SIG_DFL. Alter- nately, if the SA_RESETHAND bit is set the default action will be rein- stated when the signal is first posted. The defaults are process termi- nation, possibly with core dump; no action; stopping the process; or con- tinuing the process. See the signal list below for each signal's default action. If sa_handler is set to SIG_DFL, the default action for the sig- nal is to discard the signal, and if a signal is pending, the pending signal is discarded even if the signal is masked. If sa_handler is set to SIG_IGN, current and pending instances of the signal are ignored and discarded. Options may be specified by setting sa_flags. If the SA_NOCLDSTOP bit is set when installing a catching function for the SIGCHLD signal, the SIGCHLD signal will be generated only when a child process exits, not when a child process stops. Further, if the SA_ONSTACK bit is set in sa_flags, the system will deliver the signal to the process on a signal stack, specified with sigaltstack(2). Finally, if the SA_NOCLDWAIT bit is set in sa_flags, the system will not create a zombie when the child exits, but the child process will be automatically waited for. If a signal is caught during the system calls listed below, the call may be forced to terminate with the error EINTR, the call may return with a data transfer shorter than requested, or the call may be restarted. Restarting of pending calls is requested by setting the SA_RESTART bit in sa_flags. The affected system calls include open(2), read(2), write(2), sendto(2), recvfrom(2), sendmsg(2) and recvmsg(2) on a communications channel or a slow device (such as a terminal, but not a regular file) and during a wait(2) or ioctl(2). However, calls that have already committed are not restarted, but instead return a partial success (for example, a short read count). After a fork(2) or vfork(2) all signals, the signal mask, the signal stack, and the restart/interrupt flags are inherited by the child. The execve(2) system call reinstates the default action for all signals which were caught and resets all signals to be caught on the user stack. Ignored signals remain ignored; the signal mask remains the same; signals that restart pending system calls continue to do so. See signal(7) for comprehensive list of supported signals.
NOTES
The mask specified in act is not allowed to block SIGKILL or SIGSTOP. This is enforced silently by the system.
RETURN VALUES
A 0 value indicates that the call succeeded. A -1 return value indicates an error occurred and errno is set to indicate the reason.
EXAMPLES
The handler routine can be declared: void handler(sig, code, scp) int sig, code; struct sigcontext *scp; Here sig is the signal number, into which the hardware faults and traps are mapped. code is a parameter that is either a constant or the code provided by the hardware. scp is a pointer to the sigcontext structure (defined in <signal.h>), used to restore the context from before the sig- nal. For POSIX compliance, the sa_handler is declared to be (void (*)(int)) and the above handler will need to be casted to that type. Future ver- sions of NetBSD will replace the sigcontext interface with the siginfo interface.
ERRORS
sigaction() will fail and no new signal handler will be installed if one of the following occurs: [EFAULT] Either act or oact points to memory that is not a valid part of the process address space. [EINVAL] sig is not a valid signal number. [EINVAL] An attempt is made to ignore or supply a handler for SIGKILL or SIGSTOP.
SEE ALSO
kill(1), kill(2), ptrace(2), sigaltstack(2), sigprocmask(2), sigsuspend(2), setjmp(3), sigsetops(3), tty(4), signal(7)
STANDARDS
The sigaction() function conforms to IEEE Std 1003.1-1990 (``POSIX''). The SA_ONSTACK and SA_RESTART flags are Berkeley extensions, available on most BSD-derived systems. NetBSD 1.6.1 November 1, 1997 3

Powered by man-cgi (2024-08-26). Maintained for NetBSD by Kimmo Suominen. Based on man-cgi by Panagiotis Christias.