AGR(4) NetBSD Kernel Interfaces Manual AGR(4)
NAME
agr -- link aggregation pseudo network interface driver
SYNOPSIS
pseudo-device agr
DESCRIPTION
The driver described in this manual page is obsolete and will be removed from a future version of the system. lagg(4) should be used instead. The agr driver provides link aggregation functionality (a.k.a. L2 trunk- ing or bonding). It supports the IEEE 802.3ad Link Aggregation Control Protocol (LACP) and the Marker Protocol. The agr driver supports the following link specific flags for ifconfig(8): link0 Use the round-robin distribution algorithm. Don't use it unless you're really sure, because it violates the frame ordering rule. -link0 Use the default distribution algorithm, which is based on the hash of DA/SA, TCI, and, if available, some upper layer protocol information like ip(4) DA/SA. link1 Disable LACP. Prevents any LACP or Marker messaging which leaves the ports in the default static configuration. Set this prior to adding ports.
EXAMPLES
Create an agr interface, agr0, and attach re0 and re1 to it. In other words, aggregate re0 and re1 so that they can be used as a single inter- face, agr0. The physical interfaces which are attached to the agr inter- face must not have any IP addresses, neither IPv4 nor IPv6. ifconfig re0 inet xxx.xxx.xxx.xxx delete ifconfig re0 inet6 fe80::xxxx:xxxx:xxxx:xxxx delete ifconfig re1 inet xxx.xxx.xxx.xxx delete ifconfig re1 inet6 fe80::xxxx:xxxx:xxxx:xxxx delete ifconfig agr0 create ifconfig agr0 agrport re0 ifconfig agr0 agrport re1 Destroy an interface created in the above example. ifconfig agr0 -agrport re0 ifconfig agr0 -agrport re1 ifconfig agr0 destroy
SEE ALSO
lagg(4), ifconfig(8)
STANDARDS
IEEE 802.3ad Aggregation of Multiple Link Segments
HISTORY
The agr driver first appeared in NetBSD 4.0 and was obsoleted in NetBSD 10.0. The agr driver will be removed from NetBSD 11.0.
AUTHORS
The agr driver was written by YAMAMOTO Takashi.
BUGS
There is no way to configure LACP administrative variables, including system and port priorities. The current implementation of the agr driver always performs active-mode LACP and uses 0x8000 as system and port pri- orities. The agr driver uses the MAC address of the first-added physical interface as the MAC address of the agr interface itself. Thus, removing the phys- ical interface and using it for another purpose can result in non-unique MAC addresses. The current implementation of the agr driver doesn't prevent unsafe oper- ations like some ioctls against underlying physical interfaces. Such operations can result in unexpected behaviors, and are strongly discour- aged. There is no way to configure agr interfaces without attaching physical interfaces. Physical interfaces being added to the agr interface shouldn't have any addresses except for link level address. Otherwise, the attempt will fail with EBUSY. Note that it includes an automatically assigned IPv6 link-local address. NetBSD 10.1 February 23, 2010 NetBSD 10.1
Powered by man-cgi (2024-08-26). Maintained for NetBSD by Kimmo Suominen. Based on man-cgi by Panagiotis Christias.