bmx280thp -- Driver for Bosch BMP280/BME280 sensor chip via I2C bus
SYNOPSIS
bmx280thp* at iic? addr 0x76 bmx280thp* at iic? addr 0x77 bmx280thp* at spi? slave 0 bmx280thp* at spi? slave 1
DESCRIPTION
The bmx280thp driver provides measurements from the BMP280 and BME280 temperature, humidity and barometric pressure sensors via the envsys(4) framework. The bmx280thp addr argument selects the address at the iic(4) bus and the bmx280thp slave argument selects which chip select will be used on the spi(4) bus. The precision of the measurement which is related to the over sampling performed on the measurement can be changed through sysctl(8) nodes.
SYSCTL VARIABLES
The following sysctl(3) variables are provided: hw.bmx280thp0.osrs_t hw.bmx280thp0.osrs_p hw.bmx280thp0.osrs_h These control oversampling of temperature, pressure and humidity. The valid values are 1, 2, 4, 8, and 16 times oversample. Humid- ity is only available if the chip is a BME280. hw.bmx280thp0.irr_samples IRR is a filter that can be used to reduce the noise in the mea- surement. The value values are 1 (or off), 2, 5, 11 and 22 sam- ples to reach >= 75% of the step response. hw.bmx280thp0.waitfactor.t hw.bmx280thp0.waitfactor.p hw.bmx280thp0.waitfactor.h These control the wait multiplication factor for a measurement cycle. This factor is different for temperature, pressure and humidity and is based upon the values of osrs_t, osrs_p and osrs_h. If the chip does not return the correct measurements for a given over sampling then the wait factors can be adjusted to allow more time for the measurement to complete successfully. hw.bmx280thp0.debug hw.bmx280thp0.dump_calibration If the driver is compiled with BMX280_DEBUG, these nodes will appear and can be used to set the debugging level and provide the calibration constants, upon refresh, that are stored in the chip. Since the constants are fixed, this is a boolean node and will reset back to false once one dump has been performed. hw.bmx280thp0.readattempts A status register tells the driver if the chip is busy with a measurement. This status register must be polled and readat- tempts is the number of times that this poll will be performed. The default is 25 which should be more than enough for most pur- poses.
SEE ALSO
envsys(4), iic(4), spi(4), envstat(8), sysctl(8)
HISTORY
The bmx280thp driver first appeared in NetBSD 10.0.
AUTHORS
The bmx280thp driver was written by Brad Spencer <brad@anduin.eldar.org>.
BUGS
The driver does not support the continuous read mode that the BMP280 and BME280 has. NetBSD 10.1 November 19, 2022 NetBSD 10.1