RAID device drivers which support management functionality can register their services with the bio(4) driver. bioctl then can be used to manage the RAID controller's properties.
COMMANDS
The following commands are supported: show [disks | volumes] Without any argument by default bioctl will show information about all volumes and the logical disks used on them. If disks is specified, only informa- tion about physical disks will be shown. If volumes is specified, only information about the volumes will be shown. alarm [disable | enable | silence | test] Control the RAID card's alarm functionality, if sup- ported. By default if no argument is specified, its current state will be shown. Optionally the disable, enable, silence, or test arguments may be specified to enable, disable, silence, or test the RAID card's alarm. blink start channel:target.lun | stop channel:target.lun Instruct the device at channel:target.lun to start or cease blinking, if there's ses(4) support in the enclosure. hotspare add channel:target.lun | remove channel:target.lun Create or remove a hot-spare drive at location channel:target.lun. passthru add DISKID channel:target.lun | remove channel:target.lun Create or remove a pass-through device. The DISKID argument specifies the disk that will be used for the new device, and it will be created at the location channel:target.lun. NOTE: Removing a pass-through device that has a mounted filesystem will lead to undefined behaviour. check start VOLID | stop VOLID Start or stop consistency volume check in the volume with index VOLID. NOTE: Not many RAID controllers support this feature. create volume VOLID DISKIDs [SIZE] STRIPE RAID_LEVEL channel:target.lun Create a volume at index VOLID. The DISKIDs argument will specify the first and last disk, i.e.: 0-3 will use the disks 0, 1, 2, and 3. The SIZE argument is optional and may be specified if not all available disk space is wanted (also dependent of the RAID_LEVEL). The volume will have a stripe size defined in the STRIPE argument and it will be located at channel:target.lun. remove volume VOLID channel:target.lun Remove a volume at index VOLID and located at channel:target.lun. NOTE: Removing a RAID volume that has a mounted filesystem will lead to undefined behaviour.
EXAMPLES
The following command, executed from the command line, shows the status of the volumes and its logical disks on the RAID controller: $ bioctl arcmsr0 show Volume Status Size Device/Label RAID Level Stripe ================================================================= 0 Building 468G sd0 ARC-1210-VOL#00 RAID 6 128KB 0% done 0:0 Online 234G 0:0.0 noencl <WDC WD2500YS-01SHB1 20.06C06> 0:1 Online 234G 0:1.0 noencl <WDC WD2500YS-01SHB1 20.06C06> 0:2 Online 234G 0:2.0 noencl <WDC WD2500YS-01SHB1 20.06C06> 0:3 Online 234G 0:3.0 noencl <WDC WD2500YS-01SHB1 20.06C06> To create a RAID 5 volume on the SCSI 0:15.0 location on the disks 0, 1, 2, and 3, with stripe size of 64Kb on the first volume ID, using all available free space on the disks: $ bioctl arcmsr0 create volume 0 0-3 64 5 0:15.0 To remove the volume 0 previously created at the SCSI 0:15.0 location: $ bioctl arcmsr0 remove volume 0 0:15.0
SEE ALSO
arcmsr(4), ataraid(4), bio(4), cac(4), ciss(4), mfi(4), mfii(4), mpii(4), mpt(4)
HISTORY
The bioctl command appeared in OpenBSD 3.8, it first appeared in NetBSD 4.0 and was rewritten for NetBSD 5.0.
AUTHORS
The bioctl interface was written by Marco Peereboom <marco@openbsd.org> and was rewritten with multiple features by Juan Romero Pardines <xtraeme@NetBSD.org>. NetBSD 10.1 May 7, 2019 NetBSD 10.1